Sanitary Seals isolate the pressure measuring device from damaging impacts caused by the medium or the installation to avoid impurities download pdf datasheet
Chemical Seals are used for pressure measurement of corrosive media such as hydrochloric, sulfuric and nitric acids or chlorine. download pdf datasheet
S-Comp Seals have a large separating diaphragm (70 mm diameter) to take measurement of a narrow range, they are easy to install. pdf datasheet
Chemical Seals are used for pressure measurement of highly corrosive media. Different materials for wetted parts can be applied: Hastelloy, Nickel, Monel, Titanium, Tantalum, Teflon. download pdf datasheet
The Turbine Flowmeter RQ Measuring liquids and liquefied gases in the chemical and petrochemical industry, in the mineral oil industry and loading systems, especially for high operating pressures and low viscosities, 0.15 to 2,400 m³/h, accuracy up to ±0,15% pdf datasheet
Stationary ball valve lapping machine for the simultaneous finishing of the ball and 2 metallic sealing rings. For small and medium-sized ball workpieces with diameters of up to 300 mm.
Novaris C-Bus™ RJ45 surge protection products are specifically designed for the protection of C-Bus™ RJ45 communications wiring. The Novaris C-Bus™ RJ45 network protector is designed with primary protection elements of the C-Bus™ network pairs and secondary protection elements to provide protection for the Remote Override pairs. The Novaris C-Bus™ protector contains integrated 230V isolation to prevent equipment damage during power to earth faults but also provide efficient earth bonding during a surge event.
The RF Series is a two-wire 80 GHz FMCW radar level measurement transmitter. This measuring device is designed to suit challenging liquid level applications involving narrow tanks with long nozzles and internal obstructions such as agitators, ladders or heating coils. The minimal beam angle and dead zone make this an optimal choice for continuous, non-contact level measurement in both very small and very high tanks (up to 100 m/328 ft). pdf datasheet
Reflux Flow Transmitters combine variable area flowmeter and position sensing technology to provide both a direct reading and 4 to 20 mA transmission output in a single unit. This unique approach makes the Reflux Flowmeter an ideal choice for integration into customer equipment. Key Features & Benefits Low to medium flows 4 to 20 mA transmission Local indication pdf datasheet
The Reflex LR unit pushes the boundaries of non-contact ultrasonic level measurement. This new range of smart level instruments is capable of measuring distances in excess of 60 metres and is suitable for both solids and liquids. Using new technology developed with low frequencies, this new range is capable of measuring in extremely difficult applications including very dusty and dirty environments where most traditional ultrasonics will fail. pdf datasheet
Hycontrol’s RE Series two-wire 24 GHz FMCW radar level transmitter is designed for a broad spectrum of liquid applications, most notably for corrosive liquid products. It measures distance, level and volume of liquids and pastes, and is ideal for measuring the level of corrosive liquids in agitated tanks up to a range of 100 m/328 ft. The unique drop-shaped antenna option is perfectly suited for aggressive liquids, acids and other corrosive substances. pdf datasheet
The RD Series two-wire 80 GHz FMCW radar level transmitter is designed for demanding applications with powders in very dusty atmospheres. With its small beam angle, this radar indicator is particularly suited for continuous, non-contact level measurement in high and narrow silos, hoppers or buffer storage containers up to 100 m/328 ft. Due to the high signal dynamics of the FMCW radar, the level transmitter is ideal for low-reflective media, dust, uneven surfaces or complex silo internal structures. As it features a flush-mounted PEEK lens antenna, there is no intrusion of the antenna into the silo, bin or hopper. It is ideal for dusty products such as cement, fly ash or GGBS. pdf datasheet
The RC Series is a two-wire 24 GHz FMCW radar level transmitter for basic applications with solid products. It provides continuous, non-contact level measurement of stones, granules, flakes and other such solid products for a variety of industries. It makes an ideal solid level indicator for large or high bins and silos. pdf datasheet
The RB Series two-wire 24 GHz FMCW radar level transmitter has been developed by Hycontrol for basic liquid process applications. The device is particularly appropriate for continuous, non-contact level measurement in the chemical, petrochemical, and oil and gas industries. Options for this liquid level indicator include metallic horn antennas or PP drop antennas for condensing atmospheres and corrosive media. pdf datasheet
The advanced HART communication software Raport 2 to configure, monitor and record your HART and MODBUS instruments from Aplisens download PDF Hart Communication Tools
Hycontrol’s Reflex RA Series two-wire 80 GHz FMCW radar level transmitter is designed for hygienic liquids applications, where high precision is essential. It provides users in industries such as biochemical and food production with continuous, non-contact liquid level measurement. pdf datasheet
The portable PS-T 10 is suitable for testing shut-off valves and safety valves. The test specimens are clamped vertically and can be optimally vented by filling from below. pdf Testbench
Portable valve test bench for testing safety valves DN 10 (3/8“) - DN 80 (3“) pdf Testbench
Valve test bench for testing of safety valves and shut-off / control valves DN 15 (1/2“) - DN 500 (20“) Proven technology standardised and in modular design. Cost-effective and short delivery time. Basic program with variants and many options. pdf Testbench
Valve test bench for testing safety valves DN 15 (1/2“) - DN 400 (16“) pdf Testbench
Individual horizontal test benches for clamping shut-off and control valves, customizable, clamping force: 7,5t-1500t - Range: DN 15 to DN 1000 pdf Testbench
The horizontal test bench EFCO PS-H M series in modular design with a clamping force of 200 - 600 t for testing shut-off and control valves. Water examinations are possible in combination with air or nitrogen. pdf Testbench
Test bench with automatic test sequence for testing shut-off valves PS-7,5A / 15A - DN15 (1/2“) - DN250 (10“) pdf Testbench
The PRP Pitot Tube Flowsensor measures the flow in pipes and ducts according to the differential pressure working principle. It allows bidirectional flow with low pressure loss, low maintenance and installation cost and accurate long term reading. download pdf datasheet
Smart differential pressure transmitter PRE-28 SMART from Europe is applicable to the measurement of differential pressure. Range: -25...25 mbar, max 0-70 bar download pdf datasheet
The differential pressure transmitter PRE-28 from Europe is applicable to the measurement of differential pressure of gases, vapors and liquids. Range: 0...25 mbar upto 0-25 bar download pdf datasheet
Magnetic Level Gauge Pointer R with two process connections at the end of the level gauge, this type is suitable for mounting between two pipelines.
pdf datasheet
Magnetic Level Gauge with two or more process connections for mounting on the side of a vessel. This design is specially made for evaporating applications.
pdf datasheet